User’s Manual of ICS-10x

The page includes the following fields:

Local UDP Port

Enter the local port number

Remote Address

Enter the IP address of the remote device.

Remote Port

Enter the remote port number of the remote device.

 

 

 

 

4.4.4 Virtual COM mode

When the ICS-10x be configured to Virtual COM mode, it allows Serial device that connected to serial port of ICS-10x to establish TCP communication over Intranet or Internet network between Remote Host (Computer). The Virtual COM Port driver has to be installed at the Remote Host. Users can send data by Virtual COM port, and Virtual COM port will transfer data to Ethernet by windows socket. The Virtual COM driver maps IP Address / Port of ICS-10x to a local COM port on the Remote Host (Computer). Once the Virtual COM connection is established, the applications work as the serial device is direct connected to the Remote Host’s real COM port. After the connection is established, data can be transmitted in both directions.

With connect to ICS-10x Serial over Fast Ethernet Converter, the serial devices are not limited to physical connection to the PC/Remote Host COM port and able to be extension over longer distance. The parameter defines the maintenance status for the Virtual COM.

Figure 4-25Virtual COM Mode

When the changed operation mode, the user should be changed the Serial Port Configuration. The screen in Figure 4-14 appears.

Figure 4-26Virtual COM Configuration screen

-31-