User’s Manual of ICS-10x

The page includes the following fields:

TCP Port Number

The TCP port that ICS-10X uses to listen to connections and that other device

 

must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the

 

default is set to “1024”.

Inactive Timeout

Use the parameter to set an inactive timeout. The unit drops the connection if

 

there is no activity on the serial line before the set time expires. To disable the

 

inactive timeout enter “0”.

 

 

 

 

Example: Use PLANET VCOM Utility + Microsoft Windows Hyper terminal COM Port mode

Figure 4-27Example Virtual COM Mode

The user want to use the virtual COM like to use the serial cable connect the switch.

1.Setup Operation Mode and Serial Port of ICS-10x

2.Use PLANET VCOM Utility to create virtual COM Port

3.Hyper Terminal set up a new connection with the virtual COM port

Setup Operation Mode and Serial Port of ICS-10x

1.From the WEB interface, set the Serial operation mode of ICS-10x to “Virtual COM” and set the TCP Port Number to “23”.

-32-