User’s Manual of ICS-10x

4.4.2 TCP Client mode

When the ICS-10x be configured to TCP Client mode, it allows Serial device that connected to serial port of ICS-10x to establish TCP communication actively over Intranet or Internet network between:

„Remote Host (Computer) with Serial applications using TCP/IP network socket programs

„Other ICS-10x with TCP Server mode

After the data has been transferred, the ICS-10x can disconnect automatically from the Remote Host depends on the TCP Inactive timeout settings. The parameter defines the maintenance status for listen for the TCP connection.

Figure 4-21TCP Client Mode

The screen in Figure 4-22 appears. When the changed operation mode, the user should be changed the Serial Port Configuration.

Figure 4-22TCP Client Configuration screen

The page includes the following fields:

 

Remote Host IP

Allow the ICS-10X to connect actively to the remote host whose IP address is set

 

 

Address

by this parameter.

 

 

Remote Host Port

The remote host port number that ICS-10X uses to listen to connections and that

 

 

Number

other device must use to contact ICS-10X. To avoid conflicts with well known

 

 

 

TCP ports, the default is set to “1024”.

 

 

Inactive Timeout

Use the parameter to set an inactive timeout. The unit drops the connection if

 

 

 

there is no activity on the serial line before the set time expires. To disable the

 

 

 

inactive timeout enter “0”.

 

 

 

 

 

 

 

 

 

 

 

 

 

-29-