User’s Manual of ICS-10x

Setup Operation Mode and Serial Port of ICS-10x

1.Set the ICS-10X mode to “Telnet server mode” from web interface.

2.Set the Serial Port Configuration of ICS-10x as below:

Mode:

RS-232

Baudrare:

9600

Character Bits:

8

Parity Type :

none

Stop Bit :

1

Hardware Flow Control:

none

Execute “Telnet” command from Windows Start Menu

3.Click the Start Menu and go to Run

4.Type "telnet" without the quotes, and hit enter.

Figure 4-40Example Windows Excuse - Telnet

5.While the Telnet window appears, type “open xxx,xxx,xxx,xxx”, xxx is the IP address of the ICS-10x Telnet Server. In this case we type “open 192.168.0.100” and press enter.

Figure 4-41Example Windows Excuse - Telnet

6.Then can use the telnet connection to configure the switch just like console direct connect to the COM port of the switch.