User’s Manual of
4.5 Serial Port Configuration
The page shows the converter’s serial Port configuration. The screen in Figure
Figure
The page includes the following fields:
• Mode | From the | |
| | RS232 |
| | |
| | |
• Baudrate | The unit and attached serial device, such as a modem, must agree on a speed or | |
| baud rate to use for the serial connection, Valid baud rates. | |
| It’s in the range of 110bps to 921600bps. | |
• Character Bits | Indicates the number of the bits in a transmitted data package. The allowed value | |
| is 5,6,7,8 |
|
| The default is “8”. | |
• Parity type | Checks for the parity type. The default value is “none”. | |
• Stop Bit | The stop bit follows the data and parity bits in serial communication. It indicates | |
| the end of transmission. The default is “1”. |
•Hardware Flow Control Flow control manages data flow between devices in a network to ensure it is processed efficiently. Too much data arriving before a device is prepared to manage it causes lost or retransmitted data.
|
| XON/XOFF, RTS/CTS, DTR/DSR | |
|
| The default value is “none”. | |
| • Delimiter | Character The Character 1 and Character 2 allow the use to enter two ASCII | |
|
| character (in hex format) that delimit the beginning and end of a message. When | |
|
| a message with both there delimiters is received at the serial port, the data | |
|
|
|
|
|
|
|
|
|
|
|