User’s Manual of ICS-10x

Example: Two ICS-10x with Pair Connection modeOne be configured as Pair Connection – Local (Master)The other one be configured as Pair Connection – Remote (Slave)

Via the RS-485 interface, the external scanners, speed dome cameras and PTZ receivers can be controlled by the keyboard which provides upward, downward, leftward, rightward, clockwise and counterclockwise with the joystick. In this case, we use two ICS-10x to extend the distance between an IP surveillance PT Camera and a Control keyboard. Both of the two equipments are implemented with RS-485 interface.

The two of the ICS-10x master and slave with below settings:

 

ICS-10x Master

 

 

 

 

 

Connect to

Control Keyboard

 

 

 

 

IP Address / Subnet Mask

192.168.0.100 / 255.255.255.0

 

 

 

 

Operation Mode

Mode: Pair Connection – Local

 

TCP Port Number : 1024

 

 

 

 

 

 

 

Serial Mode: RS-485

 

 

Baudrare: 9600

 

Serial Port Configuration

Character Bits: 8

 

Parity Type : none

 

 

 

 

Stop Bit : 1

 

 

Hardware Flow Control: none

 

 

 

 

 

 

 

ICS-10x Slave

 

 

 

 

 

Connect to

Speed Dome Camera, PTZ or Scanner

 

 

 

 

IP Address / Subnet Mask

192.168.0.101 / 255.255.255.0

 

 

 

 

 

Mode: Pair Connection – Remote

 

Operation Mode

Remote Host IP Address : 192.168.0.100

 

 

Remote Host Port Number : 1024

 

 

 

 

 

Serial Mode: RS-485

 

 

Baudrare: 9600

 

Serial Port Configuration

Character Bits: 8

 

Parity Type : none

 

 

 

 

Stop Bit : 1

 

 

Hardware Flow Control: none

Topology:

 

Figure 4-49Two ICS-10x configured with Pair-Connection

-44-