Polycom 7000, 6000 manual Power-up Test Operational Test, Testing the IAD

Models: 7000 6000

1 323
Download 323 pages 54.38 Kb
Page 291
Image 291

Verification

272

Power-up Test

Operational Test

The NetEngine IAD displays an indication of normal operation when you first power it up. When you power it up, verify that the POWER indicator on the front panel lights green.

Use the following procedure to verify that the IAD is operating properly after installation. The following procedure assumes that:

You have configured Directory numbers (DNs) in the Class 5 switch for the associated Voice Ports.

The IAD has been connected to a terminal emulator via the console port, displays the normal boot sequence and you can log in.

You have configured PVCs at the DSLAM (default data = 0, 38; default voice is 0, 39) when using ATM.

You have provisioned a data network.

You connected and configured a WAN link at the associated DSLAM or voice gateway. For more information, see Chapter 6, WAN Configuration (page 51).

You have a PC with Telnet, and an Ethernet adapter running TCP/IP.

￿For more information, see Connecting via Telnet on page 16.

For testing, you and a counterpart stationed logged on to the upstream voice gateway can communicate via telephone or cell phone.

Testing the IAD

1.Verify the WAN link status:

SDSL Interface—the LINK indicator blinks while the IAD synchronizes with the DSLAM, and lights continuously when the link is established. T1/E1 Interface—the LINK indicator blinks while the IAD synchronizes with the voice gateway, and lights continuously when the link is established.

2.Connect a POTS telephone to a provisioned line port on the IAD.

3.Lift the telephone receiver and check for dial tone

If no dial tone is present, troubleshoot as necessary.

4.Repeat steps 2 and 3 for each provisioned line port.

5.Disconnect the telephone once you are through testing the line ports.

6.Use a crossover cable to connect the PC to the Ethernet LAN port on the IAD. Determine that the PC is configured with an IP address on the same subnet as the IAD.

7.Observe that the LINK indicator on the IAD front panel lights to verify that the IAD is connected to the LAN.

8.Run Ping on the PC to ping a known good address on the IAD and verify the acknowledgement.

If a timeout occurs, troubleshoot the LAN path to the IAD.

9.Ping a known good address on the network and wait for acknowledgement.

If a timeout occurs, troubleshoot the LAN path to the IAD.

10.Disconnect the Ethernet cable between the PC and the IAD.

NetEngine IAD User Guide

Page 291
Image 291
Polycom 7000, 6000 manual Power-up Test Operational Test, Testing the IAD