CHANGING VOLTAGE
The motor supplied with your saw is wired for 120 volt operation. If you desire to operate your saw at 240 volts, it is necessary to reposition voltage changing switch in the motor junction box (B) Fig. D. Proceed as follows:
1. WARNING: DISCONNECT TOOL FROM POWER SOURCE.
2.Remove screw (A) Fig. D, and remove nameplate cover (B).
3.Carefully slide switch (C) Fig. E, in motor junction box to read 240. Replace nameplate cover and screw which were removed in STEP 2.
4.It is also necessary to replace the 120 volt plug supplied with the motor with a UL/CSA listed plug suitable for 240 volts and the rated current of the saw. Contact your local Authorized Delta Service Center or qualified electrician for proper procedures to install the plug. The saw must comply with all local and national electrical codes after the 240 volt plug is assembled.
B
A
Fig. D
CURRENT | GROUNDED OUTLET BOX |
CARRYING |
|
PRONGS |
|
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
Fig. C
A
Fig. E
EXTENSION CORDS
Use proper extension cords. Make sure your extension cord is in good condition and is a
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere |
| Total Length | Gauge of |
Rating | Volts | of Cord in Feet | Extension Cord |
|
|
|
|
120 | up to 25 | 18 AWG | |
120 | 16 AWG | ||
120 | 16 AWG | ||
120 | 14 AWG | ||
|
|
|
|
120 | up to 25 | 18 AWG | |
120 | 16 AWG | ||
120 | 14 AWG | ||
120 | 12 AWG | ||
120 | up to 25 | 16 AWG | |
120 | 16 AWG | ||
120 | 14 AWG | ||
120 | 12 AWG | ||
120 | up to 25 | 14 AWG | |
120 | 12 AWG | ||
120 | GREATER THAN 50 FEET NOT RECOMMENDED | ||
|
|
|
|
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere |
| Total Length | Gauge of |
Rating | Volts | of Cord in Feet | Extension Cord |
|
|
|
|
240 | up to 50 | 18 AWG | |
240 | 16 AWG | ||
240 | 16 AWG | ||
240 | 14 AWG | ||
|
|
|
|
240 | up to 50 | 18 AWG | |
240 | 16 AWG | ||
240 | 14 AWG | ||
240 | 12 AWG | ||
240 | up to 50 | 16 AWG | |
240 | 16 AWG | ||
240 | 14 AWG | ||
240 | 12 AWG | ||
240 | up to 50 | 14 AWG | |
240 | 12 AWG | ||
240 | GREATER THAN 100 FEET NOT RECOMMENDED | ||
|
|
|
|
Fig. F | Fig. F |
5