Trouble

Probable Cause

Remedy

 

 

 

 

 

Request voltage check from power

 

Low voltage.

company and correct low voltage

Motor starts slowly or

 

condition.

 

 

fails to come up to full

Centrifugal switch not operating.

Replace centrifugal switch (qualified

speed.

personnel only).

 

 

 

 

 

Motor malfunction.

Have motor checked by a qualified

 

inspector. Repair or replace.

 

 

 

 

 

 

Power line overloaded.

Correct overload condition.

 

 

 

 

Undersized wires in supply system.

Increase supply wire size.

 

 

 

Motor fails to develop

 

Request voltage check from power

full power.

Low voltage.

company and correct low voltage

 

 

condition.

 

 

 

 

Motor malfunction.

Have motor checked by a qualified

 

inspector. Repair or replace.

 

 

 

 

 

Replacement Parts

Replacement parts are listed on the following pages. To order parts or reach our service department, call 1-800-274-6848, Monday through Friday (see our website for business hours, www.powermatic.com). Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately.

28

Page 28
Image 28