PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt has shifted to the left, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn the left rear roller adjust- ment bolt clockwise, and the right bolt counterclock- wise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b. If the walking belt has shifted to the right, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn the left rear roller adjust- ment bolt counterclockwise, and the right bolt clock- wise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

c. If the walking belt slips when walked on, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjust- ment bolts clockwise, 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each side of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

a

b

c

PROBLEM: An error code (E1, E20, E21, E22, or E23) appears on the console

SOLUTION: a. If an error code appears in one of the displays of the console, remove the key from the console, wait for a moment, and then reinsert the key. If the error code appears again, call our toll-free HELPLINE. Do not use the treadmill until the problem is corrected.

PROBLEM: The heart rate monitor does not function properly

SOLUTION: a. If the heart rate monitor does not function properly, refer to CHEST PULSE SENSOR TROUBLE- SHOOTING on page 7.

b. The CR 2032 battery may need to be replaced.

To replace the battery, locate the battery cover on the back of the sensor unit. Insert a coin into the slot in the cover, turn the cover counterclockwise, and remove it.

Remove the old battery and insert a new CR 2032 battery, making

 

 

 

 

sure that the battery is turned so the writing is on top. Make sure that

 

 

 

 

the rubber gasket is in place in the sensor unit. Replace the battery

 

 

 

 

 

CR 2032

cover and turn it clockwise to close it.

 

Battery

 

 

 

 

 

 

 

 

 

 

 

 

Rubber

 

 

Gasket

 

 

 

 

 

 

 

 

 

 

 

23

Page 23
Image 23
ProForm 795 user manual Problem The heart rate monitor does not function properly, CR 2032 battery may need to be replaced