Code 39

Code 39 — continued

Code 39 Length 1, Length 2 Programming Instructions

1.Scan the START/END bar code.

2.Scan either the Set Length 1 or Set Length 2 bar code.

3.Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent- ing the length in decimal notation.

For Code 39 bar codes, all check, data and full ASCII shift characters (even if full ASCII is enabled) are

 

included in the length calculations. Start/Stop charac-

NOTE

ters are not included.

 

4. Scan the START/END bar code.

START / END

PROGRAMMING BAR CODES

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 003

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 050

Quiet Zones

This feature enables/disables the requirement that quiet zones must be present for Code 39 bar codes.

START / END

PROGRAMMING BAR CODES

Don’t require Quiet Zones

DEFAULT

Require Quiet Zones