R

Cape Cod Wood Stove

INSTALLATION

CONNECTION TO A MASONRY

FIREPLACE

There are several kits available to connect the stove to a masonry fireplace. Look for a listed kit. The kit is an adapter which is installed at the location of the fireplace damper. The existing damper may have to be removed to allow installation of the kit. The key points of this type of stove connection are that the connector pipe must extend up the chimney above where the fire clay liner starts, and the areas of the kit installation and penetration should fit tightly and be sealed with high temperature furnace cement unless the kit’s instructions state otherwise. (See Figure 12). The tight fitting installation aids the proper draw of the chimney.

FIGURE 12

Support Plate & Clamp

Listed Rigid

Fireclay liner 5/8"

Stainless Liner

(16mm) Minimum or

 

Equivalent.

Stainless Steel

Carry Stovepipe

Above the Liner

Flex Section

 

Stainless Tee with Cleanout

Damper Plate is

Removed or

 

Stainless Connector Pipe

Fastened in Open

 

Position

Use Damper Adapter or Seal With Sheetmetal and Sealant

6

Cleanout