INSTALLATION OF OPTIONAL BLOWER, Part 831-1701

R

4300 ACT Wood Stove Series

INSTALLATION OF OPTIONAL BLOWER, Part 831-1701

The blower is shipped fully assembled and ready for installation.

1.Remove the three bolts (1/4”-20 Phillips Head) on the outer skin at the bottom rear of stove.

2.Align holes in mounting flange of blower with bolt holes in stove. Blower should be positioned around bottom of rear outer skin as shown in drawing below.

3.Re-insert and tighten bolts, securing blower onto outer wall of stove.

Do not remove ground from plug. Plug blower cord into a grounded outlet. Route power cord away from stove in such a manner to avoid heat from the stove, traffic, or other damage. Do not route cord under or in front of stove.

ADJUSTING THE BLOWER SPEED CONTROL, IF NECESSARY*

*The blower speed control for this unit is adjusted at the factory and normally does not

require further adjustment.

NOTE: When the speed control is turned clockwise, it will click on to high speed. Continue to turn the speed control clockwise to decrease the speed. At full clockwise, the blower should blow gently, but should not stop.

1.With the unit plugged in, turn the speed control knob to slow (full clockwise).

2.With a small screwdriver, adjust the blower speed by turning the adjustment mechanism through the hole on the side of the speed control.

3.Adjust the speed so the blower runs slowly, but does not stop. Turn clockwise to slow the blower and counterclockwise to increase the speed.

BLOWER SPEED CONTROL

 

Blower

Outer

Skin

Mounting

 

Flange

 

Figure 17A

(4300 Millennium Only)

TOP HEAT SHIELD INSTALLATION, Part: 831-0972

1.

Unscrew and remove the rear heat deflector.

3.

Set top heat shield on stove and push down into

 

2.

Attach the two “S” clips to the upper edge of the outer

 

“S” clips.

 

4.

Install chimney pipe through the hole in the top

 

 

wall of the stove.

 

 

 

heat shield.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 