Quadra-Fire SANTAFEI-CE-MBK D. High Ash Fuel Content Maintenance, Firepot Overfills, In Feed Tube

Models: CASTILEI-CE-MBK SANTAFEI-CE-MBK

1 36
Download 36 pages 9.8 Kb
Page 16
Image 16
D. High Ash Fuel Content Maintenance

Castile & Santa Fe CE Insert

R

D. High Ash Fuel Content Maintenance

Frequency: As needed

By: Homeowner

Poor quality pellet fuel, or lack of maintenance, can create conditions that make the firepot fill quickly with ashes and clinkers.

This condition makes the appliance susceptible to overfilling the firepot with pellets which may result in smoking, sooting and possible hopper fires. Figure 16.1 shows an example where the firepot overfills, pellets back up into the feed tube and ash has accumulated in the firebox.

An inefficient and non-economical method of burning of fuel caused by poor quality pellet fuel is shown in Figure 16.2.

The correct flame size when good quality, premium pellet fuel is burned is shown in Figure 16.3.

If the ash buildup exceeds the half way point in the firepot

IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.

Firepot Overfills

Pellets Back Up

In Feed Tube

 

Ash Build Up in Firebox

 

Figure 16.1

Incorrect

•Frequency: As needed WARNING

Fire Risk.

High ash fuels, or lack of maintenance, can cause the firepot to overfill. Follow proper shutdown procedure if ash buildup exceeds half way point in firepot.

Failure to do so could result in smoking, sooting and possible hopper fires.

Tall, Lazy Flame, Orange in Color

Figure 16.2

Correct

Correct Flame Size, Yellow/White in Color

Figure 16.3

Page 16

7069-101B

October 27, 2011

 

 

Page 16
Image 16
Quadra-Fire SANTAFEI-CE-MBK D. High Ash Fuel Content Maintenance, Firepot Overfills, Pellets Back Up, In Feed Tube