Castile & Santa Fe CE Insert

R

8 Venting Systems

A. Full Reline With Horizontal Outside Air

CAUTION

Never draw outside combustion air from:

Wall, floor or ceiling cavity

Enclosed space such as an attic or garage

WARNING

Fire Risk.

Inspection of Chimney:

Masonry chimney must be in good condition.

Meets minimum standard of NFPA 211

Factory-built chimney must be a minimum 152mm UL103 HT.

NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insu- lation such as , mineral wool or ceramic.

Do not use high temperature caulking materials to seal any edge to prevent future service- ability.

NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insu- lation such as fiberglass, mineral wool or ceramic.

Do not use high temperature caulking materials to seal any edge to prevent furture service- ability.

Outside Air through Rear Wall (Horizontal)

Outside Air through Rear Wall (Horizontal)

Figure 28.1

Figure 28.2

NOTE:

Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

Page 26

7069-101B

October 27, 2011

 

 

Page 26
Image 26
Quadra-Fire SANTAFEI-CE-MBK, CASTILEI-CE-MBK owner manual Venting Systems, Full Reline With Horizontal Outside Air