SCSI Description
Quantum Atlas 10K II Ultra160/m SCSI Hard Disk Drives 5–183
REQUEST SENSE Command (03h) (continued)
Table 5–86 Supported Additional Sense Codes and Sense Code Qualifiers (continued)
Sense Key Sense
Code Sense
Qualifier Meaning
04h HARDWARE ERROR 00 00 No Additional Sense Information
02 00 Could Not Complete SEEK
03 00 Write Fault
03 84 Diagnostics Failed, Unit is Write Protected
06 80 PES Calibration Results Are Bad
06 81 BIAS Calibration Results Are Bad
06 82 GAMMA Calibration Results Are Bad
06 83 Recalibration Record Timeout
06 84 Seek Fail During Feedforward Scal
Calibration
06 85 Initial Track Grab Failed
06 86 Seek Failure During Bias Calibration
06 87 Seek Failure During FT/J Calibration
06 88 Seek Failure During PES Calibration
06 89 Recalibration Servo Not Ready
06 8A Switch Point Calibration Results Are Bad
06 8B Recalibration Track Number Bad
06 8C Seek Failure During Switch Point
Calibration
06 8D Not All Head(s) in USER Head Map Were
Found Alive
06 8E Valid SAM(s) Not Found
(continued)