Quantum 3.5 manual Operating Label for System LUNs 1 TB LUNs 1-2 TB LUNs 2 TB

Models: 3.5

1 178
Download 178 pages 38.95 Kb
Page 23
Image 23

Table 3 Required Disk LUN Labels

Chapter 1 Installing StorNext File System and Storage Manager Getting Ready to Install

of the operating system running on the MDC as well as the operating system running on all connected clients. Disk LUNs can have one of three labels: VTOC, EFI, or sVTOC (short VTOC).

Required disk LUN label settings based on operating system and LUN size are presented in Table 3. Before installing StorNext, decide what label type will be used, and then install any required operating system patches or updates (for both MDC and client) as indicated in the notes for Table 3.

Note: After labeling a disk LUN, you must reboot systems running Solaris before they can access the disk LUN.

Operating

Label for

Label for

Label for

System

LUNs < 1 TB

LUNs 1–2 TB

LUNs > 2 TB

 

 

 

 

Windows XPa

VTOC, EFI

VTOC, EFI

EFI, sVTOC

Windows 2003

VTOC, EFI

VTOC, EFI

EFI, sVTOC

Server

 

 

 

 

 

 

 

Linux 2.6

VTOC, EFI

VTOC, EFI

EFI, sVTOC

Kernel

 

 

 

 

 

 

 

Linux 2.4

VTOC, EFI

VTOC, EFI

Not supported

Kernel

 

 

 

 

 

 

 

Solaris 9b

VTOC, EFI

EFI

Not supported

Solaris 10c

VTOC, EFI

EFI

EFI

HP-UXa

VTOC, EFI

VTOC, EFI

EFI, sVTOC

IBM AIXd

VTOC, EFI

VTOC, EFI

EFI, sVTOC

SGI IRIX

VTOC

VTOC

Not supported

 

 

 

 

Apple Xsan 1.3

VTOC, EFI

VTOC, EFI

EFI, sVTOC

(MacOS X 10.4

 

 

 

Tiger)

 

 

 

 

 

 

 

Apple Xsan 1.3

VTOC, EFI

VTOC, EFI

EFI, sVTOC

(MacOS X 10.3

 

 

 

Panther)a

 

 

 

StorNext 3.5 Installation Guide

6

Page 23