![](/images/new-backgrounds/1117563/117563297x1.webp)
Procedure A: EMC Legato NetWorker
Procedure A: EMC Legato NetWorker
1Start the Windows Registry Editor program (as shown in figure 48) as follows:
a a. Select Start>Run.
b b. Enter the following value in the Open text box: regedt32 c c. Press [Enter].
Note: You can also open this program at the following location:
%SystemRoot%\Winnt\System32\regedt32.exe
2Select Window> HKEY_LOCAL_MACHINE> System> CurrentControlSet> Services> QntmDLT (or depending on tape device being tested) to make that window active.
3Select Edit>Add Key and enter Parameters for Key Name to create a key named Parameters, if one does not exist.
4To create a key named Device, open the Parameters key by selecting Edit>Add Key and enter Device for Key Name.
5To create a DWORD named MaximumSGList, open the Device key by selecting Edit>DWORD and entering MaximumSGList for DWORD Name.
6Open the MaximumSGList Value Name and replace the existing Value Data in Decimal with a number at least as large as the block size you need for the device.
To calculate the value, use the following equation: (Block_Size / 4) + 1 = Value
Note: Block Size Decimal Value Hex Value:
•64k 17 decimal 11 hex
•96k 25 decimal 19 hex
•128k 33 decimal 21 hex
•256k 65 decimal 41 hex
•512k 129 decimal 81 hex
Quantum TC2201 User’s Guide | 129 |