Setting the Time Table Program

The time table program function allows automatic selection of print color (black or red), an external time signal, and automatic selection of a column to print records in. These functions can be set by the day of the week and time period.

No time table program is factory-set. (The default is: print in black; no external time signal; and print in Column 1.)

The PROGRAM button stays lit up during its setting operation.

The time table program is explained using the following example.

Day advance time:

 

Next day

05:00

12:00

05:00

Sunday

Print in red/in Column 5

Print in red/in Column 6

 

 

 

"P-01"

 

 

 

 

"P-02"

 

 

Day advance time:

 

 

 

 

 

 

 

 

Next day

 

05:00

09:00

12:00

17:30

05:00

Monday - Saturday

 

Print in black/

 

Print in red/

Print in red/

 

Print in black/

 

 

 

in Column 1

 

in Column 2

in Column 3

 

in Column 4

 

 

 

 

 

 

 

"P-03"

 

"P-04"

 

 

"P-05"

 

 

 

 

Signal

 

 

Signal

 

 

The following is the time table based on the case above.

Program No.

Day of week

Time

Print color

External time

signal

 

 

 

 

P-01

Sun.

05:00

Red

 

P-02

Sun.

12:00

Red

 

P-03

Mon. - Sat.

09:00

Red

 

P-04

Mon. - Sat.

12:00

Red

 

P-05

Mon. - Sat.

17:30

Black

 

Print column

5

6

2

3

4

Times are always printed in black in Column 1 for the time period with no program setting.

One programmed day begins at the day advance time.

 

See "Setting Day Advance Time" in this section for details.

18

Up to 32 programs can be set (P-01 through P-32).

 

Page 20
Image 20
Quartz 500 operation manual Setting the Time Table Program