FIFO polled mode operation (16550 UART only)
The receiver and transmitter are operated independently, which would allow either or both to be used in a polled mode rather than using interrupts to determine when the UART needs to be serviced.
To use the UART in a polled mode, the software is responsible for continuously checking for the conditions that normally cause interrupts to occur. This would be done using the Line Status Register.
1.The Data Ready bit will be set to logic 1 whenever there is at least one byte in the receive FIFO.
2.Errors can be detected using the various error bits.
3.The Transmitter Holding Register Empty bit can be used to determine when the transmit FIFO is empty.
4.The Transmitter Empty bit indicates that the transmitter shift register is empty as well as the transmit FIFO being empty.
5.Trigger levels and FIFO timeouts do not apply. Both FIFOs are fully capable of holding multiple characters at any time.