Chapter 4 - Control from the Supervisory Port HCD-E1
Installation & Operation Manual
4-38 HCD-E1 Command Set Description 11/01/00 19:23
Note
In case the CRC-4 function is disabled, HCD-E1 displays an error message:
ILLEGAL COMMAND FOR CURRENT MODE. If the CRC-4 function is enabled
on the sublink of the local unit, but disabled at the remote end, HCD-E1 will
display meaningless information.
DSP REM AGENT Purpose
Display information on the SNMP agents that are known to the IP router of
the HCD-E1 when SNMP management is enabled.
Note
For SNMP management to be enabled, the following conditions must be
satisfied:
1. The units must have different IP addresses and different MUX_NAME’s.
2. A dedicated slot must be assigned in both units.
Syntax
DSP REM AGENT
Use
To display the remote agent information, type:
DSP REM AGENT
If not all conditions listed above are fulfilled, HCD-E1 displays the following
message:
CAN NOT FIND REMOTE AGENT
Otherwise, HCD-E1 displays a table listing the remote agents. A typical
display is shown below:
IP ADDRESS MUX NAME DISTANCE
--------------------------------------
192.114.50.2 RAD1 006
192.114.50.3 RAD2 012
The fields displayed for each agent are as follows:
IP ADDRESS The IP address of the remote agent (see the DEF
AGENT command above).
MUX NAME The logical name of the remote agent (see the DEF
NAME command above).
DISTANCE The distance is a metric that indicates the logical
distance (through the management network) to the
remote agent, and is used, among other factors, in the
selection of the optimal route to be used by the
management traffic.