Chapter 3 - Front Panel Operating Instructions HCD-E1
Installation & Operation Manual
3-26 Local Configuration Setup Procedure 11/01/00 19:52
3. To reassign closed time slots to a data channel, scroll to CHANNEL
PRM CHX in the top row. Set the SPEED parameter to the
corresponding (higher) value. For each time slot you want to reassign,
scroll to the time slot in the bottom row and set it to DATA. When the
reassignment of the desired time slots is completed, press ENTER.
4. To reassign closed time slots to the sublink, scroll to SL PARAMTERS in
the top row. Set the NUM OF TS parameter to the corresponding
(higher) value. For each time slot you want to reassign, scroll to the time
slot in the bottom row and set it as desired. When the reassignment of
the desired time slots is completed, press ENTER.
Replacing a Time Slot Used for the In-band Management
Before selecting a new time slot for the main link in-band management, you
must close the current dedicated time slot.
1. Scroll to DNLOAD PRM in the top row, scroll to ML TS NUM in the
bottom row.
2. Scroll to the current dedicated timeslot and close it by setting it to NC.
Wait 20 seconds (40 seconds if H-RPT is installed in the HDSL link).
Note
Make sure that the time slot, which you intend to use for the in-band
management is not assigned to a data channel or sublink.
3. Assign the desired timeslot to the in-band management from the
DNLOAD PRM menu.