Chapter 4 - Control from the Supervisory Port HCD-E1
Installation & Operation Manual
4-44 HCD-E1 Command Set Description 11/01/00 19:23
Display Format
A typical sublink status display is shown below.
STATUS OF PORT
TYPE = E1
FUNCTION = DSU
ALARMS = L. SYNC LOSS
============ R. SYNC LOSS
============
OFF OFF
LOOPS = REM PORT
======== REM REM PORT
============ LOCAL PORT
==========
NO NO NO
BPV LAST MINUTE = 0
BPV WORST MINUTE = 1
The fields included in the status information display are listed below:
TYPE Displays the type of the sublink interface: E1
FUNCTION Displays the type of interface hardware installed on the
user's port: LTU or DSU
ALARMS Indicates the status of the sublink alarms. The
displayed alarms depend on the framing mode:
For G732N, this field shows the local and remote
‘loss of frame alignment’ alarms.
For the unframed mode, L. SYNC LOSS shows the
‘loss of signal’ alarm. R. SYNC LOSS is meaningless.
LOOPS Displays the state of each type of loopback that can be
activated on the user's port.
BPV LAST MINUTE Displays the number of BPV events detected in the last
minute. This counter is displayed only when the CRC-4
function is disabled.
BPV WORST MINUTE Displays the number of BPV events detected in the
worst minute. This counter is displayed only with
CRC-4 disabled.
DSP ST SYS Purpose
Display system status information.
Syntax
DSP ST SYS