HCD-E1 Installation & Operation Manual Chapter 4 - Control from the Supervisory Port
11/01/00 19:23 HCD-E1 Command Set Description 4-49
INIT DB Purpose

Erase the user-defined configuration from the database and load the

database with a specified set of default parameters values (see Table 4-2).

Syntax

INIT DB

Use

Type:

INIT DB<CR>

This command loads the default parameters and resets the HCD-E1.

Note

Traffic through HCD-E1 may be interrupted until you configure it anew.

Table 4-2 HCD-E1 Default Configuration

Parameter Type Parameter Designation Default Value
General PASSWORD
NODE (node number)
CLEAR SCREEN
CURSOR HOME
CURSOR RIGHT
HCD
0
1B5B324A
1B5B4800
1B5B3143
SYSTEM CLK_MASTER
CLK_FBACK
CONFIG REM
INT
NONE
YES
SL (sublink) FRAME
CRC-4
SYNC
IDLE_TS_CODE
MAP_TYPE
NUM_OF_TS
Time Slots
G732N
NO
CCITT
FF
USER
NC
NC
SP (control port) SPEED
DATA
PARITY
INTERFACE
CTS
DCD_DEL
DSR
POP_ALM
PWD
LOG_OFF
AUXILIARY DEVICE
AUTO
8
NONE
DCE
=RTS
0_MS
ON
NO
NO
NO
TERMINAL
CH1/CH2 FRAME
MULTIPLIER
MAP_TYPE
SPEED
CTS
FIFO_SIZE
CLOCK_MODE
Time Slots
FRAMED
64
USER
NC
ON
AUTO
DCE
NC