HCD-E1 Installation & Operation Manual Chapter 3 - Front Panel Operating Instructions
11/01/00 19:52 Configuration Parameters 3-7
Additional Functions of ENTER
The ENTER key has two additional functions:
1. When the LCD displays the ALARM BUFFER screen, the ENTER key can
be used to delete all the alarm messages in the buffer.
2. When the LCD displays the PORT DIAG or HDSL DIAG screens, the
ENTER key can be used to reset the performance monitoring counter
being displayed (see Displaying Performance Data on the Front-Panel
LCD in Chapter 5).
3.4 Configuration Parameters
This section lists the HCD-E1 configuration parameters and their functions.
The information is organized in tables for each group of parameters:
Group Display See...
System parameters SYSTEM PARAMETER Table 3-2
Sublink parameters SL PARAMETERS Table 3-3
Control port
parameters
SP PARAMETERS Table 3-4
Channel parameters CHANNEL PRM Table 3-5
BERT parameters BERT PRM Table 3-6
Download
parameters
DNLOAD PRM Table 3-7
Priority bumping
parameters
PB PARAMETERS Table 3-8
The tables also list the parameter values included in the HCD-E1 default
configuration and important practical guidelines for configuring some of
them.
Note
In addition to the parameters listed in the tables, HCD-E1 supports other
parameters, which can be modified only via the control port. These
parameters are explained in Chapter 4.
System parameters can be set only on a unit configured as central.