Chapter 5 - Troubleshooting and Diagnostics HCD-E1
Installation & Operation Manual
5-4 Status Indications and Alarms 01/01/01 08:15
Table 5-1 HCD-E1 Alarm Buffer Messages (Cont.)
LCD Message Terminal Message Alarm
Number
Probable Cause Corrective Actions Alarm
Type
DB-INIT DW IS ON DB-INIT SWITCH IS ON 21 Section DB INIT is set to ON.
This message appears only upon
power-up.
If it is no longer necessary to enforce the default
database parameter values, change setting to OFF.
ON
DIAL CYCLE FAIL* DP DIAL CYCLE FAILED* 44 The current cycle of call
attempts (both to the primary
and alternate numbers) failed.
Check the modem connected to the CONTROL
DCE connector. If the called numbers are often
busy, you may also increase the number of call
retries
ON
DIFF DEDIC TS DIFFERENT DTS
CENTRAL & REMOTE
39 The time slot assigned for
management in the central unit
and in the remote unit are not
the same time slot
Select the time slots assigned for management
correctly.
ON/OFF
DP ALT CALL FAIL* DP ALTERNATE CALL
FAILED*
46 The call attempts to the alternate
dial-out number failed
If the number is not busy, check the modem
connected to the CONTROL DCE connector. If
the called numbers (primary as well as alternate)
are often busy, you may also increase the number
of call retries
ON
DP PRM CALL FAIL* DP PRIMARY CALL
FAILED*
45 The call attempts to the primary
dial-out number failed
If the number is not busy, check the modem
connected to the CONTROL DCE connector. If
the called number is often busy, you may also
increase the number of call retries
ON
Note
Alarms 44, 45 and 46 appear only when you perform a DSP ALM REM command and you have HTU-E1 or HTU-2 at theremote site.