Appendix E - IR-IP Interface Module HCD-E1
Installation & Operation Manual
E-8 Performing Preliminary Configuration
4. Send a ping to the new address to be used by IR-IP. A confirmation
should be received after the third ping: after the confirmation, the
flashing will slow down to approximately twice a second.
If your host does not begin to receive ping replies after three
unsuccessful attempts, skip to the What to Do If ... section below.
5. Return section 1 of the IR-IP DIP switch to the OFF position.
The ERR indicator must turn off.
At this stage, the communication with IR-IP router is lost, because its IP
address has been changed. Therefore, you must reconfigure the destination
IP address of the Telnet host. If you wish, you may also change the
temporary IP address assigned to the host (192.168.205.2) back to its
permanent address.
After changing the destination IP address of the Telnet host, it is
recommended to turn HCD-E1 off for a few seconds and then back on,
before continuing the configuration of the IP router in accordance with the
Quick Setup Menu section below. At this time, in Step 2 the ERR indicator
turns off after the 15-second interval.
Changing the LAN IP Address of a Configured IR-IP
The LAN IP address of an already-configured IR-IP can be changed while it
operates, this means it is not necessary to turn HCD-E1 off before starting
the configuration procedure. Note however that the IP traffic flow through
IR-IP will be disrupted until the other stations in the IP network learn the
new address.
To change the LAN IP address of an already-configured IR-IP, use the
procedure described above for a new IR-IP with the following differences:
1. Configure the destination address of the ping utility to the new LAN
interface IP address. It is not necessary to change the Telnet host source
address.
2. When ready, set section 1 of the IR-IP DIP switch to ON.
The ERR indicator starts flashing faster (approximately four times a
second).
3. Perform Steps 4, 5 of the procedure used for a new IR-IP.
What to Do If ...
After HCD-E1 is turned on, the INT indicator does not light
The IR-IP interface module does not receive power from the HCD-E1 power
supply. Service is required.
After HCD-E1 is turned on, the ERR indicator does not light
IR-IP is faulty and must be replaced.