HCD-E1 Installation & Operation Manual Chapter 4 - Control from the Supervisory Port
11/01/00 19:23 HCD-E1 Command Set Description 4-51
To activate Type
BERT test on data channel X of HCD-E1
In-band loopback on data channel X of the remote unit
Local (L) loopback on the HDSL lines (only from the unit
configured as central)
Local (L) loopback on data channel X of local HCD-E1
Remote (R) loopback on data channel X of local HCD-E1
Remote (R) loopback on data channel X of remote unit
Local (L) loopback on the E1 sublink of the local HCD-E1
Remote (R) loopback on the E1 sublink of the local
HCD-E1
Remote (R) loopback on the E1 sublink of the remote unit
Local loopback on H-RPT (only from the unit configured as
central)
LOOP BERT CH X, or LP BERT CH X*
LOOP INBAND CH X, or LP INBAND CH X*
LOOP L LINE, or LP L LINE
LOOP L CH X, or LP L CH X*
LOOP R CH X, or LP R CH X*
LOOP R R CH X, or LP R R CH X*
LOOP L SL, or LP L SL
LOOP R SL, or LP R SL
LOOP R R SL, or LP R R SL
LOOP L HRPT, or LP L HRPT
HCD-E1 performs the requested command and displays the date and time,
followed by the HCD-E1 prompt.
RESET Purpose
Reset HCD-E1. This command causes HCD-E1 to initialize, therefore the
traffic through HCD-E1 will be disrupted until HCD-E1 returns to normal
operation.
Syntax
RESET
Use
To reset HCD-E1, type:
RESET<CR>