USING THE KEYPAD DIAGNOSTIC
The
1.Hold down MO (REV) and turn on the transceiver.
2.Press MO (REV) again. PrESS dn appears.
3.Press . If the action is correct, PrESS Up appears.
4.Press . If the action is correct, PrES Mr appears.
5.Press MR (MW). If the action is correct, PrESS Sc appears.
6.Press SC (RPT). If the action is correct, PrESS bp appears.
7.Press (BEEP). If the action is correct, PrESS Lc appears.
8.Press LOCK (C). If the action is correct, F appears.
9.Press FUNC. If the action is correct, PrES Mo appears.
10.Press MO (REV). If this action is correct, GOOD appears briefly and then the set frequency appears again.
RESETTING THE HTX-400
If the transceiver’s display locks up or the transceiver does not work properly after you turn it on, you might need to reset it.
Caution: This procedure clears all the information you have pro- grammed into the transceiver. Before you reset the transceiver, try turning it off then on again to see if it begins working properly.
To reset the transceiver, turn it off then hold down FUNC +MO and turn it on again. iniTial appears to confirm the reset opera- tion. Release FUNC+MO.
44