Radware VOYA-GRAND-MBK E. Metal Heat Circulating Masonry, F. Prefabricated Metal Chimney

Models: VOYA-GRAND-PMH VOYA-GRAND-MBK

1 56
Download 56 pages 43.75 Kb
Page 36
Image 36
E. Metal Heat Circulating Masonry

VOYAGEUR GRAND Wood Insert

R

E. Metal Heat Circulating Masonry

This insert conforms with the safety standard UL-1482 and ULC S628 (Canada) in all respects and is approved to UL & ULC safety standards for installation and use within a fire- place with masonry chimney, in accordance with NFPA 211, and CAN/CSA-B365-01.

F. Prefabricated Metal Chimney

The chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements:

•Must be minimum 6 inch (152mm) inside diameter of high temperature chimney listed to UL 103 HT (2100oF) or ULC S628.

•Must use components required by the manufacturer for installation.

•Must maintain clearances required by the manufacturer for installation.

•Refer to manufacturers instructions for installation

•This insert is listed to UL 1482 Standard and is approved for installation into listed factory-built solid fuel fireplaces listed to UL 127 conforming to the follow- ing specifications and instructions:

•The original factory-built clearance fireplace chimney cap must be re-installed after installing the approved chimney liner meeting type UL 103 HT requirements (2100°F) per UL 1777.

•The liner must be securely attached to the insert flue collar and the chimney top.

•The air flow of the factory-built solid fuel fireplace system must not be altered. The flue liner top support attachment must not reduce the air flow for the existing air-cooled chimney system.

•No dilution air is allowed to enter the chimney.

1.Secure the fireplace damper in the open position.

If this cannot be accomplished, it will be necessary to remove the damper.

2.Seal damper area of chimney around chimney connector with a high temperature sealant or seal insert against the face of the fireplace.

3.Both methods must be removable and replaceable for cleaning and re-installation.

 

Inches

Millimeters

Minimum Width of Cavity Opening - Front

32-7/8*

835

Minimum Width of Cavity Opening - Rear

24*

610

Minimum Height

24*

610

Minimum Depth from Front to Rear

18*

457

*You will need to add additional clearances to these dimensions for your specific installation. Also allow suf- ficient clearance if you are installing an outside air kit.

NOTE: Refer to chimney liner manufacturer for recom- mendations on supporting the liner. Installation into fireplaces without a permit will void the listing.

NOTICE: In Canada when using a factory-built chimney it must be safety listed, Type UL103 HT (2100oF) [1149oC] CLASS “A” or conforming to CAN/ULC-S629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS.

WARNING

Fire Risk.

When lining air-cooled factory-built chimneys:.

Run chimney liner approved to UL 1777 Type HT requirements (2100 degrees F)

Re-install original factory built chimney cap

ONLY

DO NOT block cooling air openings in chimney

Blocking cooling air will overheat the chimney

To maintain the functionality of the fireplace’s chimney system you may use a Simpson Dura-Vent DuraLiner Slip Hanger, Part # 4671, and attach to the bottom of the fireplace chimney cap to support the liner. You have two options to completing the installation.

Option one - Not required to use liner cap: Re-attach the existing top of the chimney cap.

Option two - Using liner cap:

Re-attach the existing top of the chimney cap and install a new storm collar and a new liner cap.

WARNING! Risk of Fire!

Follow venting manufacturer’s clearances and instructions when installing venting system.