Image 44

VOYAGEUR GRAND Wood Insert

R

Green Grounding

Wire

 

 

Remove Screw

 

 

 

 

 

 

Figure 44.4

 

 

6. Remove the screw that is holding the ground lug

Figure 44.1

 

to the control plate.

4.Remove the 2 screws at the top of the control plate. Push the bottom of the control plate to the inside of the appliance and partially remove the control plate assembly.

White Wire

Black Wire

 

 

Figure 44.5

 

 

7. Use needle nose pliers to remove the strain relief

 

that protects the power cord from the control plate.

Figure 44.2

5. Locate the black and white wires that are part of the power cord and disconnect those wires from the wire harness.

Placement Slot

Blower Access

Assembly

Grille hinges

Hold Down

downward

Bracket

 

Figure 44.3

 

Snap Disc Bracket

Remove Screws &

Blower Control Plate

 

Pull Access Assembly

Remove Screws from Hold Down

away from Insert

Bracket and Pull Blower Assembly

 

 

Forward. Do not Remove Blower from

 

the Hold Down Bracket