Technical Data

Technical Data

This cooker is category II2H3+

It is supplied set for either:-

a) group H natural gas or b) LP gas.

A conversion kit from NG to LP gas is available.

INSTALLER: Please leave these instructions with the User.

DATA BADGE LOCATION:

Cooker back, serial number repeater badge below oven door opening.

Country of Destination: GB/IE

Gas

 

Electric

Natural Gas

20mbar

220 - 240V 50Hz

Butane

29mbar

 

Propane

37mbar

 

(See appliance data badge for test pressures)

Dimensions

 

 

Overall height

 

minimum 893mm maximum 920mm

Overall width

 

1100mm See ‘Positioning of Cooker’

Overall depth

 

648mm

Space for fixing

 

See ‘Positioning of Cooker’

Minimum space above hotplate

650mm

Connections

Gas:

Electric

Rp 1/2 at rear right-hand side

220 - 240V 50Hz

Ratings

 

Natural Gas

L.P. Gas

 

 

 

Injector

 

Injector

Hotplate

 

 

 

 

Wok burner

3.5kW

internal 80

3.5kW (246g/h)

internal 54

 

 

external 129

 

external 77

Large Burner

3.0kW

134

3.0kW (210g/h)

87

Medium Burners

1.7kW

109

1.7kW (119g/h)

68

Small Burner

1.0kW

75

1.0kW (70g/h)

51

Gas burner inputs based on Gross Calorific Value

Ovens

Conventional Oven

 

Fan Oven

 

Oven

Browning Element

 

 

2.2kW

1.15kW

2.5kW

Grill

2.3kW

 

 

Warmer

160W

 

 

Maximum total electrical load at 230V 7.2kW*

*approximate total including oven lights, oven fan etc.