8. Operation

use. (F8-11)

(1)Normal operating mode

(2)Anti-freeze mode

(3)Cylinder cover

(4)‘Sun shine’ mark

(5)‘Snow’ mark

Manual backgroundWARNING

Continuing to use the product in anti-freeze mode even when temperatures have risen and returned to normal may result in the engine failing to start properly or in the engine failing to operate at its normal speed, and for this reason you should always be sure to return the unit to normal operating mode if there is no danger of icing occurring.

HOW TO SWITCH BETWEEN OPERATING

MODES (F8-12)

1.Flip the engine switch to turn off the engine.

2.Remove the cover to the air filter, remove the air filter, and then remove the choke knob from the cylinder cover.

3.Loosen the screws holding the cylinder cover in place (i.e., the three screws on the inside and the one screw on the outside of the cover), and then remove the cylinder cover.

4.Press with your finger down on the icing cap located on the right-hand side of the cylinder cover to remove the icing cap.

5.Adjust the icing cap so that the “snow” mark faces upwards and then return it to its original position in the cylinder cover.

6.Fix the cylinder cover back into its original position, and then fix all other parts back into their proper positions.

(1)Choke knob

(2)Cylinder cover

(3)Icing cap