Regency E21-NG2 Installation, Conversion Kit# 534-969from NG to LP, LPG Conversion Kit Contains

Models: E21-NG2 E21-LP2

1 32
Download 32 pages 58.92 Kb
Page 17
Image 17
Conversion Kit# 534-969 from NG to LP

INSTALLATION

Conversion Kit# 534-969 from NG to LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

Each Kit contains one LPG Conversion Kit and one DC Sparker Kit.

LPG Conversion Kit Contains:
Qty. Part #Description

1

904-163

Burner Orifi ce #54

1

904-529

5/32" Allen Key

1918-590 Label "Converted to LPG"

1

908-528

Red "LPG" label

1

910-037

LP Injector (Pilot Orifi ce)

1

910-233

Thermodisc Switch

1

918-482

Instruction Sheet

DC Sparker Kit Contains:

Qty. Part #

Description

1

820-475

Bracket DC Sparker

1

820-476

Bracket DC Sparker

1

904-153

Washer #8 External Star

1

904-330

Nut 8-32 Hex

1904-438 Plug Nylon 0.750 Hole, Black

1904-531 Bushing Split Plastic

0.500 in.

6) Remove the Grate by removing the

10) Remove burner orifi ce with 1/2"

screws on each side of the grate.

wrench. Use another wrench to hold

 

onto the elbow behind the offi ce

 

Replace with the #54 orifi ce in the Kit.

Remove the 2 screws holding

Burner

Orifi ce

the grate in position.

 

7) Remove the Burner Tray by removing 1

11) Turn control knob to the “OFF”

screw on each side of the tray, then slide

position.

the tray to the left and lift out.

 

 

12) Remove the black protection cap by

 

hand from the high-low knob (Fig.1).

1904-543 Screw 8-32 x 3/4 Pan Head

2904-553 Screw #8 x 1/2 Type "B",

Black Oxide

1

910-073

Spark Generator Battery

 

 

Holder

1910-074 Spark Generator Switch C/W Wire

1

910-078

Battery Size AA

 

 

Energizer En91

1

910-199

Clip Wire Holder

1

910-903

Wire Fan To Power Cord

 

 

Ground 30 in.

 

904-781

Velcro Hook, Black

 

904-782

Velcro Hook, Black

Installation of LPG

Conversion Kit:

1)Turn the unit off and allow it to cool to room temperature.

2)Shut off glass supply

3)Unplug or disconnect power source to stove.

4)Remove glass front (see Door Glass Replacement section in the manual).

5)Remove logs and brick panels (if installed).

Remove the 2 screws,

push Burner Tray to the left, and lift off.

8)Pull off the pilot cap to expose the pilot orifi ce.

9)Unscrew the pilot orifi ce with the allen key (provided) and replace with the LP pilot orifi ce in the kit.

Fig. 1

13)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

Fig.2

Regency® E21-2 Gas Fireplace Insert

17

Page 17
Image 17
Regency E21-NG2, E21-LP2 Installation, Conversion Kit# 534-969from NG to LP, If In Doubt Do Not Do This Conversion, Qty