MAINTENANCE

AUTOMATIC

CONVECTION FAN

OPERATION

The fan operates automatically, turn the knob on the side of the faceplate to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperature. After the unit has been turned off and the unit cooled to below a useful heat output range the fan will shut off automatically.

NORMAL OPERATING

SOUNDS OF GAS

APPLIANCES

It is possible that you will hear some sounds from your gas appliance.This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples.All are normal operatingsoundsandshouldnotbeconsidered as defects in your appliance.

Blower:

Regency® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.

Burner Tray:

The burner tray is positioned directly under the burner tube(s) and logs and is made of a different gauge material from the rest of the fi rebox and body.Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.

Blower Thermodisc:

When this thermally activated switch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal.

Pilot Flame:

While the pilot fl ame is on it can make a very slight "whisper" sound.

Gas Control Valve:

As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.

Unit Body/Firebox:

Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.

MAINTENANCE

INSTRUCTIONS

1)Always turn the gas valve to off before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year.

When cleaning the logs, use a clean soft paint brush as the logs are fragile and easily damaged.

2)Clean (never when unit is hot) appliance, door and louvers with a damp cloth. Never use an abrasive cleaner. The gold louvers (and optional gold door) may be scratched if abrasives are used to clean them.

The heater is fi nished in a heat resistant paint and should only be refi nished with heat resistant paint (not with wall paint). Regency® uses StoveBrite Paint - Metallic Black #6309.

3)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the fl ames are steady; not lifting or fl oating. If there is a problem, call a qualifi ed service person.

4)The appliance and venting system must be inspected before use, and at least annually, by a qualifi ed fi eld service person, to ensure that the fl ow of combustion and ventilation air is not obstructed.

During the annual service call, the burners should be removed from the burner tray and cleaned. Replace the embers but do not block the pilot.

5)Keep the area near the appliance clear and free from combustible materials, gasoline and other fl ammable vapours and liquids.

6)Each time the appliance is lit, it may cause condensation and fog the glass. This condensation and fog is normal and will disappear in a few minutes as the glass heats up.

Neveroperatetheappliancewithout the glass properly secured in place or with the door open.

7)Verify proper operation after servicing.

8)Periodically check the pilot fl ames, see the diagrams in the "Valve Description" section. If you have an incorrect fl ame pattern, contact your Regency® dealer for further instructions.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISEDWHENTHEYAREINTHE SAME ROOM AS THE APPLIANCE.

CAUTION: ANY SAFETY SCREEN OR GUARDREMOVEDFORSERVICINGAN APPLIANCEMUSTBEREPLACEDPRIOR TO OPERATING THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANCE.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

GLASS GASKET

If the glass gasket requires replacement use 7/8" fl at glass gasket (Part # 936-243) for the Bay Front and for the Flush Front.

GOLD-PLATED

ACCESSORIES

The24caratgoldplatedfinishontheaccessories requires little maintenance, and need only be cleanedwithadampcloth. DO NOTuse abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty.

Clean any fingerprints off before turning the unit on. If the top louvers start to discolour, check the door gasket seal and replace if necessary.

Regency® E21-2 Gas Fireplace Insert

25

Page 25
Image 25
Regency E21-NG2, E21-LP2 installation manual Maintenance

E21-NG2, E21-LP2 specifications

The Regency E21-LP2 and E21-NG2 are modern gas fireplaces that embody style, efficiency, and advanced engineering, making them standout choices for homeowners seeking both aesthetic appeal and functional utility. These models are designed to complement a wide variety of interior decor styles while providing warmth and comfort.

One of the most prominent features of the E21 series is its high-efficiency heating capability, which allows these fireplaces to generate a significant amount of heat while using minimal fuel. The E21-LP2, designed for liquid propane, and the E21-NG2, designed for natural gas, ensure versatile installation options for different home setups. Homeowners can select the fuel type that best suits their needs or local availability.

The design of the Regency E21 models is marked by a large viewing area, providing an unobstructed view of the mesmerizing flames. The impressive flame pattern not only adds to the ambiance but also creates a warm and inviting focal point in any living space. The elegant, clean lines and contemporary frame enhance the fireplace's visual appeal, making it an excellent choice for modern interiors.

In terms of technology, both models are equipped with the advanced IntelliFire ignition system, which offers reliability and ease of use. This system ensures that igniting the fireplace is straightforward and safe, freeing homeowners from the hassles of traditional methods. Furthermore, the built-in programmable thermostat allows for precise temperature control, ensuring optimal comfort levels with minimal environmental impact.

Moreover, the Regency E21 series is constructed with high-quality materials designed to offer durability and longevity. The fireplaces come with a variety of finish options, allowing homeowners to personalize their units to match their specific tastes and styles. The E21 models also feature a convenient glass safety barrier, which enhances safety while maintaining the fireplace's aesthetic appeal.

With an emphasis on energy efficiency and environmental responsibility, the E21-LP2 and E21-NG2 are not only stylish additions to any home but also economically favorable choices for homeowners. By combining practical features with contemporary design, Regency has created fireplaces that cater to modern living while providing comfort and elegance. Whether for new installations or upgrades to existing spaces, these models are sure to impress.