Regency E21-NG2, E21-LP2 installation manual Installation, Installer Notice

Models: E21-NG2 E21-LP2

1 32
Download 32 pages 58.92 Kb
Page 19
Image 19
Installer Notice:

INSTALLATION

29)Locate the ground lug at the receptical box, left of the unit.

30)Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.

33)Plug the DC spark generator wires to the DC Sparker.

34)Connect the ground wire to the DC Sparker mounting bracket.

Chain

37b) Recommended location to mount the DC Sparker.

Ground

wire from

kit

31)Install the 1/2" bushing to the heat shield.

35)Install the supplied battery into the DC Sparker Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box will need to be replaced annually.

37c) Note: Remove the bottom louver by unscrewing the four screws located on the hinges.

Battery

Compartment

32) Run the other end of the ground wire

36) Mount the heat shield to the DC Sparker.

Secure into place with the velcro, which

and DC spark generator wires through

is provided in the kit.

the bushing on the heat shield.

 

Heat Shield

 

37a) Find a location which is not too hot and is easy to reach for changing the battery. Note: It should be kept away from the chain.

38)Tie up the loose wire with the wire clip.

39)Check for gas leaks.

40)Check inlet and outlet pressures.

41)Check operation of fl ame control.

42)Check for proper fl ame appearance and glow on logs.

Installer Notice:

These instructions must be left with the appliance.

Regency® E21-2 Gas Fireplace Insert

19

Page 19
Image 19
Regency E21-NG2, E21-LP2 installation manual Installation, Installer Notice