REMOTE CONTROL

INSTALLATION

REMOTE CONTROL

WALL SWITCH

WALL THERMOSTAT

Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fi replace to that location. Use Thermostat Wire Table.

2)Connect the two wires to the gas valve. See diagram below.

CAUTION

Do not wire millivolt remote control wires to 120V wire.

1)Run the wire through the right or left side inlet opening. Be careful not to damage the wire.

Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.

2)Connect the wire to the supplied wall switch and install into the receptacle box.

CAUTION

Do not wire millivolt

wall switch wire

to 120V wire.

A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length.

Note: Preferable if the thermostat is installed on an interior wall.

Regency offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

CAUTION

Do not wire millivolt wall thermostat wires to 120V wire.

3)Install 3AAAalkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

OFF

 

L

L

 

TH

 

 

 

I

O

 

 

To wall switch,

 

 

P

 

 

 

 

NO

T

O

 

 

 

remote control

 

 

IH

TP

 

 

 

 

or thermostat

 

 

 

 

 

 

 

 

 

 

THTP

 

 

 

 

 

 

 

To thermopile

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

 

14 GA.

50

Ft.

 

16 GA.

32

Ft.

 

18 GA.

20

Ft.

 

20 GA.

12

Ft.

 

22 GA.

9

Ft.

 

22

Regency® E21-2 Gas Fireplace Insert

Page 22
Image 22
Regency E21-LP2 Installation, Remote Control, Wall Switch, Wall Thermostat, Do not wire millivolt wall switch wire