Regency U32-NG3 THE KENSINGTON 3-PANELDOOR INSTALLATION, Optional Wall Thermostat, Final Check

Models: U32-NG3

1 36
Download 36 pages 49.37 Kb
Page 20
Image 20
THE KENSINGTON

INSTALLATION

THE KENSINGTON

3-PANEL DOOR INSTALLATION

1)Install the Sub-Frame by hooking the top flange onto the top of the Glass Door and swing the Sub-Frame towards the unit. Pull out the hooks which already secure the Glass Door and place them thru the holes in the bottom of the Sub-Frame to secure both the Glass Door and Sub-Frame in place together.

Glass Door

Sub-Frame

Sub-FrameOPTIONAL WALL

Hook

OPTIONAL WALL

THERMOSTAT

A wall thermostat may be installed if desired, follow the wiring diagram below. FPI offers an optional programmable thermostat but any 250- 750 millivolt rated non-anticipator type thermo- stat that is CSA, ULC or UL approved may be used.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

 

 

 

14 GA.

50

Ft.

16 GA.

32

Ft.

18 GA.

20

Ft.

20 GA.

12

Ft.

22 GA.

9

Ft.

CAUTION

Do not connect the millivolt wall

thermostat wires to the 120V wires.

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:

1)Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) at 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer.

2)Mount the 3-panel Screen Door / Frame Assembly to the flange on Sub-Frame, ensuring to line-up holes. Secure using the 4 screws provided.

OPTIONAL REMOTE

CONTROL

Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location. Use Thermostat Wire Table.

2)Connect the wires as per the wiring dia- grams below.

CAUTION

Do not connect the millivolt

remote control wires for

to the 120V wires.

3)Install 3 AAA alkaline batteries in transmit- ter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

20

U32-3 FPI Direct Vent Gas Insert

Page 20
Image 20
Regency U32-NG3 THE KENSINGTON 3-PANELDOOR INSTALLATION, Optional Wall Thermostat, Final Check, Optional Remote Control