OPTIONAL DOUBLE DOOR FIRE SCREEN

INSTALLATION

Diagram 2

Use the hook to pull the spring out until you can

put the hook into the slot on the bottom door bracket. Repeat for 2nd spring.

See diagram 3.

Diagram 4

OPTIONAL DOUBLE DOOR FIRE SCREEN

1)Pull out the top louver.

2)Center the screen door and hook over

the flush door.

Diagram 5

11)Push the Regency logo plate into the two holes in the bottom left corner of the face- plate.

STANDARD

FLUSH DOOR

Diagram 3

To remove the flush door, reverse the above steps.

NOTE: The chain must rest on TOP of the gas inlet pipe never under it.

3)Open the screen door(s) and secure the screen door to the flush door front with 2 clips on the bottom left and right side.

Clip locations

The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1. Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. Diagram 2.

Diagram 1a

Diagram 1b

 

 

Clip installed

OPTIONAL

on right side.

 

FLUSH TRIM

 

FLUSH LOUVERS

 

 

Attach 2 round magnets to the back of the top

 

trim piece and the other 2 to the bottom trim

1) The top louver is held in place by friction fit,

piece, then attach trim to the top and bottom of

if the louver needs to be adjusted; bend the

Flush door.

bracket out as shown in the diagram.