MAINTENANCE

6)Each time the appliance is lit, it may cause condensation and fog the glass. This con- densation and fog is normal and will disap- pear in a few minutes as the glass heats up.

Never operate the appliance without the glass properly secured in place or with the door open.

7)Do not use this appliance if any part has been under water. Immediately call a qual- ified service technician to inspect the appli- ance and to replace nay part of the control system and any gas control which has been under water.

8)Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile and 1 around the thermocouple, and 1 flowing across the rear of the burner (it does not have to be touching the burner).

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These compo- nents should be replaced immediately.

2)Remove the Termination Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive conden- sation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having exces- sive lateral runs, too many elbows, and exterior portions of the system being ex- posed to cold weather.

4)Inspect joints, to verify that no pipe sections or fittings have been disturbed, and conse- quently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

Clean any fingerprints off before turning the unit on. If the top louvers start to discolour, check the door gasket seal and replace if necessary.

DOOR GLASS

Your FPI insert is supplied with high tempera- ture, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized FPI dealer only, and follow our step- by-step instructions for replacement.

Warning: Do not operate appliance with glass panels removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Caution: Wear gloves when removing damaged or broken glass.

Flush Glass Replacement

Top View of pilot flame

LOG REPLACEMENT

Incorrect flame pattern will have small, proba-

The unit should never be used with broken logs.

bly yellow flames, not coming into proper con-

Turn off the gas valve and allow the unit to cool

tact with the rear of the burner or thermopile.

before opening door to carefully remove the

 

 

logs. The pilot light generates enough heat to

 

burn someone. If for any reason a log should

 

need replacement, you must use the proper

 

replacement log. The position of these logs

 

must be as shown in the diagram under Log

 

Installation.

Remove the flush door front (as per instruc- tions on page 11). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame.

Top View of pilot flame

If you have an incorrect flame pattern, contact your FPI dealer for further instructions.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s perform- ance which is not covered under warranty.

GLASS GASKET

If the glass gasket requires replacement use glass gasket (Part # 936-265) for the Bay Front and a tadpole gasket for the Flush Front (Part

# 936-155).

GOLD-PLATED TRIM

The 24 carat gold plated finish on the trim requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abra- sive materials or chemical cleaners, as they may harm the finish and void the warranty.

24

U32-3 FPI Direct Vent Gas Insert

Page 24
Image 24
Regency U32-NG3 installation manual General Vent Maintenance, Door Glass, Glass Gasket, GOLD-PLATED Trim

U32-NG3 specifications

The Regency U32-NG3 is an innovative and elegant gas fireplace designed to enhance the ambiance of any living space while providing efficient heating. With its sleek design and modern technology, the U32-NG3 is a prime example of Regency's commitment to quality craftsmanship and customer satisfaction.

One of the main features of the U32-NG3 is its clean, contemporary lines that fit seamlessly into both traditional and modern interiors. The fireplace boasts a large viewing area, thanks to its expansive glass front. This design not only provides an unobstructed view of the flames but also allows for greater heat output, making the U32-NG3 an efficient choice for heating.

The U32-NG3 is designed with a direct vent system, which ensures that combustion gases are vented outside the home, promoting a clean indoor environment. This feature also maximizes the efficiency of the fireplace, as it draws air from outside for combustion, reducing heating costs. The direct vent technology is particularly beneficial for homes in colder climates as it minimizes the draw of warm air from the living space.

In terms of heating capacity, the U32-NG3 is powerful, capable of delivering up to 30,000 BTUs. This output is suitable for medium to large rooms, ensuring a cozy atmosphere on cold winter evenings. Homeowners can also customize the flame height and heat output to suit their comfort needs.

Safety is a top priority with the U32-NG3. It includes advanced safety features such as an automatic shut-off system that activates in case of a malfunction or blockage in the venting system. The fireplace also has a safety screen that prevents unintended contact with the flames while allowing for maximum heat circulation.

The U32-NG3 is equipped with state-of-the-art electronic ignition, which ensures quick and reliable startups at the push of a button. Additionally, the fireplace can be operated remotely with a convenient wall switch or optional remote control, adding further ease of use.

In conclusion, the Regency U32-NG3 is a versatile gas fireplace that combines style, efficiency, and advanced technology. Its focus on safety, ease of use, and impressive heating capabilities make it an ideal choice for homeowners looking to upgrade their living space with a modern heating solution. With the U32-NG3, you can create a warm and inviting atmosphere while enjoying all the benefits of a high-quality gas fireplace.