MAINTENANCE
6)Each time the appliance is lit, it may cause condensation and fog the glass. This con- densation and fog is normal and will disap- pear in a few minutes as the glass heats up.
Never operate the appliance without the glass properly secured in place or with the door open.
7)Do not use this appliance if any part has been under water. Immediately call a qual- ified service technician to inspect the appli- ance and to replace nay part of the control system and any gas control which has been under water.
8)Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile and 1 around the thermocouple, and 1 flowing across the rear of the burner (it does not have to be touching the burner).
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system
1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These compo- nents should be replaced immediately.
2)Remove the Termination Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.
3)Check for evidences of excessive conden- sation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having exces- sive lateral runs, too many elbows, and exterior portions of the system being ex- posed to cold weather.
4)Inspect joints, to verify that no pipe sections or fittings have been disturbed, and conse- quently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.
Clean any fingerprints off before turning the unit on. If the top louvers start to discolour, check the door gasket seal and replace if necessary.
DOOR GLASS
Your FPI insert is supplied with high tempera- ture, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. Do not clean the glass when hot.
In the event that you break your glass by impact, purchase your replacement from an authorized FPI dealer only, and follow our step-
Warning: Do not operate appliance with glass panels removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.
Caution: Wear gloves when removing damaged or broken glass.
Flush Glass Replacement
Top View of pilot flame | LOG REPLACEMENT | |
Incorrect flame pattern will have small, proba- | The unit should never be used with broken logs. | |
bly yellow flames, not coming into proper con- | ||
Turn off the gas valve and allow the unit to cool | ||
tact with the rear of the burner or thermopile. | ||
before opening door to carefully remove the | ||
| ||
| logs. The pilot light generates enough heat to | |
| burn someone. If for any reason a log should | |
| need replacement, you must use the proper | |
| replacement log. The position of these logs | |
| must be as shown in the diagram under Log | |
| Installation. |
Remove the flush door front (as per instruc- tions on page 11). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame.
Top View of pilot flame
If you have an incorrect flame pattern, contact your FPI dealer for further instructions.
NOTE: Improper positioning of logs may create carbon
GLASS GASKET
If the glass gasket requires replacement use glass gasket (Part #
#
GOLD-PLATED TRIM
The 24 carat gold plated finish on the trim requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abra- sive materials or chemical cleaners, as they may harm the finish and void the warranty.
24 |