INSTALLATION
1) | Check all clearances to combustibles, page |
| 6. |
2) | Make the gas connection. See page 7. |
3) | Install the 3" flue liner to the sliding connec- |
| tor plate. See page 7. |
4) | Slide the unit half way into the fireplace. |
5) | Pull the vent connector plate through the |
| tapered brackets and fasten to the front |
| plate. See page 7. |
6) | Slide the unit fully into the fireplace. |
7) | Test gas pressure, page 8. Check aeration |
| system, page 8. |
8) | Install the optional brick panels. See page 8. |
9) | Install the log set. See page 9. |
10) Assemble and install the faceplate and trim. | |
| See page 10. |
MATERIALS REQUIRED
No electrical power supply is required for the gas control to operate. A 120 Volt AC power cord is hooked up to the fan. Plug the 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any circum- stances. When connected with 120 volts, the appliance must be electrically grounded in ac- cordance with local codes, current version of CSA C22.1 (in Canada) or in the absence of local codes, with the National Electrical Code ANSI/NFPA
NOTE: This unit is equipped with a heat sensor thermodisc which will prevent the blower from operat- ing until the unit reaches the cor- rect temperature.
MINIMUM FIREPLACE
DIMENSIONS
CLEARANCES TO COMBUSTIBLES
Minimum Clearances to Combustibles
From Unit |
| |
Sides | A | 10" / 255 mm |
Ceiling | B | 47.5" / 1205 mm |
Mantel | C | see Dia. 2 & 3 |
From Standard Surround (26" x 40") | ||
Sides | D | 4" / 100 mm |
Ceiling | E | 41.5" / 1055 mm |
Mantel |
| see Dia. 2 & 3 |
Max. Mantle Depth | G | 12" / 305 mm |
|
| (see Dia. 2) |
Hearth Height | H | 0" / 0 mm |
Hearth Depth | I | 16" / 405 mm |
Hearth Width | J | 40" / 1015 mm |
Min. Alcove Width | K | 48" / 1220 mm |
Max. Alcove Depth | L | 36" / 915 mm |
11) Install the glass front (flush or bay). See | |
pages 10 and 11. | |
12) Install optional glass trim, or door fire | |
screens. See pages 11 and 12. | |
13) Install both louvers (flush or bay). See | |
pages 11 and 12. | |
14) Install optional remote control or wall ther- | |
mostat, pages 20. | |
15) Final check: Before leaving this unit with | |
the customer, the installer must ensure that | |
the appliance is firing correctly. This in- | |
cludes: | |
a) | Clocking the appliance to ensure the |
| correct firing rate. |
b) | Adjusting the primary air, if required, to |
| ensure that the flame does not carbon. |
| See page 8. |
c) | Ensuring that the appliance is venting |
| correctly. |
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1)Ensure that structural members are not cut or weakened during installation.
2)Ensure proper grounding using the #8 ground lug provided.
3)Appliance must be anchored to the floor with the supplied anchoring methods.
The minimum fireplace clearances & dimen- sions for the FPI gas insert are shown in the following diagrams:
Diagram 1
Combustible Mantel Clearances
with Bay & Flush Louvers in
Masonry and Factory Built
Fireplace Installation
*Note: If you are installing the Molded Faceplate, the minimum fireplace dimen- sions are as follows:
Width (at front): 29" | (737mm) | |
Depth: | 15" | (381mm) |
Diagram 2