Ricoh FV-G030B1 3Camera Operational Modes, 3.1Normal Mode, 3.2Pulse Width Trigger Mode, 11/38

Models: FV-G030B1

1 38
Download 38 pages 11.47 Kb
Page 11
Image 11
3Camera Operational Modes

3Camera Operational Modes

3.1Normal Mode

I nt er nal VD

CCD

exposur e

Vi deo out

Ex posur e

t i me

3.2Pulse Width Trigger Mode

In this trigger mode with positive polarity, the camera exposure starts at the rising edge of the trigger pulse and stops at the falling edge of the trigger pulse. Therefore, if positive polarity exposure is selected, the exposure periods are the high states of the trigger pulse.

3.2.1Timing

*Note. 1

Max. 1H

Trigger signal

(Positive

Internal VD

 

 

 

*Note. 2

 

 

 

Exposure

 

 

 

CCD exposure

 

 

time

 

 

 

 

Video out

FVAL

Note 1: The video output is going to be V reset by the next internal HD signal immediately after the exposure is finished. The exposure time is set by the pulse width of the trigger signal.

Note 2: The FVAL signal does not output when the exposure by the trigger signal does not exist.

FV-G030B1

11/38

User’s Guide Rev. 1.02

 

Page 11
Image 11
Ricoh FV-G030B1 3Camera Operational Modes, 3.1Normal Mode, 3.2Pulse Width Trigger Mode, 3.2.1Timing, User’s Guide Rev