Command No.

Command Description

 

 

 

30H: [7..0]

[Vertical_1 position for the ALC weight area]

1

2

3

31H: [15..8]

Initial data: 32, data range: 0 to 1,235

4

5

6

 

 

 

Sets the vertical 1 position for the ALC weight area.

7

8

9

 

 

32H: [7..0]

[Vertical_2 position for the ALC weight area]

1

2

3

33H: [15..8]

Initial data: 444, data range: 0 to 1,235

4

5

6

 

 

 

Sets the vertical 2 position for the ALC weight area.

7

8

9

 

 

34H: [7..0]

[Vertical_3 position for the ALC weight area]

1

2

3

 

 

 

35H: [15..8]

Initial data: 792, data range: 0 to 1,235

4

5

6

 

Sets the vertical 3 position for the ALC weight area.

7

8

9

36H: [7..0]

[Vertical_4 position for the ALC weight area]

1

2

3

37H: [15..8]

Initial data: 1,204 data range: 0 to 1,235

4

5

6

 

Sets the vertical 4 position for the ALC weight area.

7

8

9

 

 

38H: [7..0]

[Horizontal_1 position for the ALC weight area]

1

2

3

39H: [15..8]

Initial data: 36, data range: 0 to 1,623

4

5

6

 

 

 

Sets the horizontal 1 position for the ALC weight area.

7

8

9

 

 

3AH: [7..0]

[Horizontal_2 position for the ALC weight area]

1

2

3

3BH: [15..8]

Initial data: 577, data range: 0 to 1,623

4

5

6

 

Sets the horizontal 2 position for the ALC weight area.

7

8

9

 

 

3CH: [7..0]

[Vertical_3 position for the ALC weight area]

1

2

3

3DH: [15..8]

Initial data: 1,047, data range: 0 to 1,623

4

5

6

 

Sets the horizontal 3 position for the ALC weight area.

7

8

9

 

 

3EH: [7..0]

[Vertical_4 position for the ALC weight area]

1

2

3

3FH: [15..8]

Initial data: 1,588, data range: 0 to 1,623

4

5

6

 

Sets the horizontal 4 position for the ALC weight area.

7

8

9

 

 

FV-G200B1

33/38

User’s Guide Rev. 1.02

 

Page 33
Image 33
Ricoh FV-G200B1 manual 33/38