RIDGID K-40B Accessories, Maintenance Instructions, K-40Drain Cleaner, Ridge Tool Company

Models: K-40 K-40B K-40G PF

1 51
Download 51 pages 23.17 Kb
Page 15
Image 15
Accessories

K-40 Drain Cleaner

Accessories

Only the following RIDGID products have been designed to function with the K-40/K-40B Drain Cleaning Machines. Other accessories suitable for use with other tools may be- come hazardous when used on the K-40/K-40B. To pre- vent serious injury, use only the accessories listed below.

Catalog

Number

Standard Machine Cable with Cable End Indicator:

C-13-IC SB Speedbump Cable..........5/16x 35

95847

Other Optional Cables:

 

C-1IC Cable with Bulb Auger .............5/16x 25

56782

C-2 Cable with Drop Head Auger ......5/16x 25

62235

C-2-IC Cable with Drop Head Auger..5/16x 25

56787

C-22 Cable with Drop Head Auger ....5/16x 50

89405

C-13-IC Cable with Bulb Auger ..........5/16x 35

56792

C-23-IC Cable with Drop Head ..........5/16x 35

56797

C-4 Cable with Male Coupling.............3/8x 25

62245

C-5 Cable with Bulb Auger..................3/8x 35

62250

C-6 Cable with Male Coupling.............3/8x 35

62260

C-6-IC Cable with Male Coupling........3/8x 35

96037

Inner Drum

68917

Autofeed A-39/40 PF

67962

Guide Hose A-40G

71757

Guide Hose & Autofeed A-40G PF

71762

(See Figure 24.)

 

Mounting Bracket A-40B

72702

Torque Arm

71847

Automotive Battery Charger

84117

Top Roller Holder Housing Assembly

76597

C-6 Cable Kit

76817

C-6-IC Cable Kit Includes:

98072

C-6-IC Cable, Inner Drum, Torque Arm, T-250 Tool Set

14.4V Battery Pack

83407

115V Charger

83417

230V Charger

84112

Figure 24 – Guide Hose and Autofeed A-40G PF

Maintenance Instructions

Maintenance Instructions WARNING

Make sure machine is unplugged from power source before making any adjustment.

1.Cables should be thoroughly flushed with water after each use to prevent damaging effects of drain clean- ing compounds. RIDGID Cable Rust Inhibitor should be applied prior to storage.

When not in use, store cables indoors to prevent de- terioration by the elements.

NOTE! Cables should be replaced when they become severely corroded or worn. A worn cable can be identified when outside coils of cables be- come flat.

2.Use a clean cloth to wipe the unit off. Oil, grease and other substances may cause deterioration. Certain cleaning agents and solvents damage plastic parts. Some of these are: gasoline, carbon tetrachloride, chlorinated cleaning solvents, ammonia and house- hold detergents that contain ammonia. Avoiding use of these and other types of cleaning agents mini- mizes the probability of damage.

3.It is a good idea to regularly drain the inner drums of any captured liquid. Simply hold the machine nose down and drain excess liquid each time the machine is used.

NOTE! Remove the Guide Hose accessory for ease of draining.

4.Store the unit where it is cool and dry. Avoid those areas where the temperature will drop to 0°F or ex- ceed +120°F.

Ridge Tool Company

13

Page 15
Image 15