M A I N T E N A N C E & S E R V I C E I N F O R M AT I O N
MAINTENANCE SUGGESTIONS
This water heater has been designed and constructed for a long performance life when installed and operated properly under normal conditions. Regular inspections, as outlined in this section, are strongly recommended as a means of keeping your heater operating efficiently.
1. Cleaning
The water heater must be cleaned annually. Keep the water heater clear of dust and debris especially in and around burner.
Cleaning procedures for the Continuum are as follows:
1)Turn off and disconnect electrical power. Allow to cool for one hour.
2)Remove the Front Panel by removing screws. See parts breakdown on panels.
3)Use pressurized air to remove dust from around main burner.
4)Use soft dry cloth to wipe cabinet.
DO NOT DAMAGE OR DISTORT ANY PARTS OF HEATER.
DO NOT USE WET CLOTH OR SPRAY CLEANERS ON BURNER.
2. Visual check of main burner flames.
The burner must flame evenly over the entire sur- face when operating correctly. The flame must burn with a clear, blue, stable flame. See the parts breakdown of the burner for the location of view ports. Any and all parts removed for inspection or service must be replaced before operating the unit. The flame pattern should be as shown in the fol- lowing Figures.
*VENT MAINTENANCE
*VENT SYSTEM
Must be checked annually for blockage or deterioration.
* MAINTENANCE- ELECTRIC MOTORS
Motors are permanently lubri- cated and need no lubrication. Keep fan and motor free of dust and dirt, clean annually.