Rinnai manual Model 2424WC, PCB. Note Connect remote control cable to, right

Models: 2424WC

1 48
Download 48 pages 41.6 Kb
Page 35
Image 35
PCB. Note: Connect remote control cable to

INSTALLER’S INSTALLATION INSTRUCTIONS

Remote Controls - Installation

1)Determine a suitable location for the control.

2)Make three holes on the wall as shown.

3)Run the cable between the control and the Continuum 2424WC or the control and the other control.

outline of remote

securing screw location labeled “TERMINAL” in the drawing at

wire hole

1 1/16”

3 1/4”

(21/32” dia.)

securing screw

Note: Remote Control Dimensions are:

4 3/4” H x 4 3/4 W” x 1” D

4)Remove the face plate from the remote control, using a screw driver.

5)Connect the cable to the remote control.

6)Mount the control to the wall using the holes drilled in step 2.

Note: If the cable cannot be run in the wall cavity, the plastic knockout should be re- moved from the top or bottom of the control to allow flush mounting with the wall

7)Disconnect the power from the Continuum 2424WC.

8)Remove the cover of the Continuum 2424WC.

9)Remove the plastic cover from the PCB and electrical connections.

DO NOT ATTEMPT TO CONNECT THE REMOTE CON-

 

TROLS WITH THE POWER ON, THERE'S 120 VOLT PO-

 

TENTIAL, NEXT TO THE REMOTE CONTROL CONNEC-

 

TIONS INSIDE THE UNIT. All service and wiring should be

 

performed by a certified installer.

TERMINAL

10) Thread the cable through the access hole at the

CLAMP

base of the unit and connect the wires to the con-

 

trol terminals on the right hand side bottom of the

 

PCB. Note: Connect remote control cable to

 

location labeled “TERMINAL” in the drawing at

 

right.

 

11)Secure the control cable using the clamp provided.

12)Replace plastic cover over PCB and then replace the cover of the Continuum 2424WC.

Model 2424WC

3 5

800-621-9419

Page 35
Image 35
Rinnai Model 2424WC, PCB. Note Connect remote control cable to, location labeled “TERMINAL” in the drawing at, right