INSTALLER’S INSTALLATION INSTRUCTIONS
Remote Controls - Installation
1)Determine a suitable location for the control.
2)Make three holes on the wall as shown.
3)Run the cable between the control and the Continuum 2424WC or the control and the other control.
outline of remote
securing screw
wire hole | 1 1/16” | |
3 1/4” | ||
(21/32” dia.) |
securing screw
Note: Remote Control Dimensions are:
4 3/4” H x 4 3/4 W” x 1” D
4)Remove the face plate from the remote control, using a screw driver.
5)Connect the cable to the remote control.
6)Mount the control to the wall using the holes drilled in step 2.
Note: If the cable cannot be run in the wall cavity, the plastic knockout should be re- moved from the top or bottom of the control to allow flush mounting with the wall
7)Disconnect the power from the Continuum 2424WC.
8)Remove the cover of the Continuum 2424WC.
9)Remove the plastic cover from the PCB and electrical connections.
DO NOT ATTEMPT TO CONNECT THE REMOTE CON- |
| |
TROLS WITH THE POWER ON, THERE'S 120 VOLT PO- |
| |
TENTIAL, NEXT TO THE REMOTE CONTROL CONNEC- |
| |
TIONS INSIDE THE UNIT. All service and wiring should be |
| |
performed by a certified installer. | TERMINAL | |
10) Thread the cable through the access hole at the | CLAMP | |
base of the unit and connect the wires to the con- | ||
| ||
trol terminals on the right hand side bottom of the |
| |
PCB. Note: Connect remote control cable to |
| |
location labeled “TERMINAL” in the drawing at |
| |
right. |
|
11)Secure the control cable using the clamp provided.
12)Replace plastic cover over PCB and then replace the cover of the Continuum 2424WC.
Model 2424WC | 3 5 |