STOP!! READ THE SAFETY ISSUES ON PAGES 8 & 9

INSTALLER’S INSTALLATION INSTRUCTIONS

Lighting the Unit

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

1)This water heater does not have a pilot. It is equipped with a direct ignition device which automatically lights the burner. DO NOT TRY TO LIGHT THE BURNER BY HAND.

2)Before operating the Continuum 2424WC smell all around the unit for gas. Be sure to smell near the ground as leaking gas may settle there.

3)Turn the manual gas control valve on.

STOP!! READ THE SAFETY ISSUES ON PAGES 8 & 9

4)Turn on any hot water tap. The Continuum 2424WC should light and begin heating your water.

If the Continuum 2424WCfails to light

1)DO NOT ATTEMPT TO LIGHT BY HAND.

2)Turn off the electrical power to the unit.

3)Turn off the manual gas control.

4)Wait 5 minutes, if you smell gas, go to a neighbor's house and call the gas company or the fire department. If you do not smell gas, go to the next step.

5)Turn the manual gas control valve on.

6)Turn the electrical power to the unit on.

7)Turn on any hot water tap.

8)If the unit still fails to light, turn off the electricity and gas to the unit and call Rinnai 1-800-621-9419.