S P E C I F I C A T I O N S

 

Appliance - AC 120 Volts - 60Hz.

 

 

 

Remote control DC 12 Volts (Digital)

 

 

 

 

 

 

 

Flame failure - Flame rod

 

 

 

 

 

 

 

Boiling protection - 203°F

 

 

 

 

 

 

 

Remaining flame (OHS) 194°F bi-metal switch

 

 

 

 

 

Safety devices

Thermal fuse 279°F

 

 

 

 

 

 

Automatic frost protection - Bi metal sensor & anti-frost heaters

 

 

 

 

 

Combustion fan rpm check - Integrated circuit

 

 

 

 

 

 

Over current - Glass fuse (3 amp)

 

 

 

 

 

 

If remote fails or becomes disconnected unit defaults to 100°F with water

 

flowing, this is an anti-scald feature.

 

 

 

 

 

 

 

Remote control

MCC-45-3 US

Main control

 

 

 

 

 

 

Remote control cable

Non-polarized two core cable

 

 

 

 

 

 

 

 

Top of heater

12"

 

 

 

 

 

 

 

 

Front of heater

24"

 

 

 

 

 

 

 

Clearances from combustibles

Sides of heater

6"

 

 

 

 

 

 

 

Back of heater

0"

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

12"

 

 

 

 

 

 

 

Below eaves, porches, overhangs = 36"

 

 

 

 

Minimum and Maximum gas supply pressure

Natural Gas : *Minimum 6" W. C.

Propane Gas: *Minimum 10" W. C.

(NAT.)

**Maximum 10.5" W. C.

(LPG)

**Maximum 14" W. C.

 

 

 

 

 

Manifold Gas Pressure

Natural Gas

5.3" W. C. high fire

 

0.43" W. C. low fire

LPG:

 

8.7" W. C. high fire

 

0.59" W. C. low fire

 

 

 

 

 

 

Warranty

Five years heat exchanger / five years parts (see unit's warranty for details)

 

 

 

 

 

 

*Minimum input pressure is for the purpose of input adjustments. **Do not exceed maximum pressure.