Venting

2. Assemble and Adjust the Sleeve Length

Measure wall thickness through previously drilled 3 1/2 inch (90 mm) hole.

The end of the sleeve should protrude 3/16 - 3/8 inch (5-10 mm) from the outside wall.

In the FOT-203 (Vent Kit A) there are 4 parts provided with which to assemble the sleeve. Use the table to determine which pieces to assemble.

In both kits, two parts are threaded for additional adjustment.

Adjust the sleeve length to wall thickness plus 3/16 - 3/8 inch (5-10 mm).

a b c

Sleeve Parts

For wall thickness plus 3/16 - 3/8 in (5-10 mm)

Assemble these parts (“A” Vent Kit)

4 1/3 - 6 1/8 in (110 - 155 mm)

 

a

+

b

 

6 1/8 - 7 3/4 in (155 - 195 mm)

a

+

b

+

c

7 3/4 - 9 1/2 in (195 - 240 mm)

a +

b

+

c

+ c

 

 

 

 

 

 

3.Attach the sleeve

Attach to the inside wall using 3 screws arranging the flange so that the marking “TOP” is at the top.

The flange is offset 2° to allow the condensate to drain to the outside.

3 screws

sleeve should extend 3/16 - 3/8 in (5-10 mm)

4. Install the Terminal

Terminal seal

Check that the terminal seal is in place. For weatherboard or vinyl siding, add the second seal next to the terminal seal to compensate for the angle.

From the outside insert the terminal into the sleeve with the marking “TOP” at the top. The left hand side locking tie should be marked “LEFT”.

Terminal

Locking tie

Rinnai Corporation RHFE-750ETRA

21

Page 21
Image 21
Rinnai RHFE-750ETRA installation manual + c