Fault Codes

Fault Codes

If there is a malfunction the appliance may shut down as a safety precaution and display a fault code to assist in diagnosing the problem. The fault code will flash in the Fault Code Display window and the Operation Indicator will flash green.

Code

Fault

Remedy

 

 

 

 

 

Confirm that the gas supply is turned on. Switch appliance to

11

Ignition failure

STANDBY and then ON again. If ignition failure continues

 

 

then a Service call is required.

 

 

 

12

Incomplete combustion

Service call

 

 

 

 

 

Clean filters

 

 

If overheating continues then a service call is required to

14

Filter blocked or Overheat

determine the cause.

 

 

Thermal fuse; a qualified service technician must replace the

 

 

fuse following the procedure below.

 

 

The temperature has reached 104° F (40° C). Turn the

16

Room overheat

appliance off or engage the AUTO OFF function to prevent the

 

 

display of flame. See AUTO OFF section.

 

 

 

31

Room temperature sensor faulty

Service call

 

 

 

32

Overheat temperature sensor 2 faulty

Service call

 

 

 

33

Overheat temperature sensor 1 faulty

Service call

 

 

 

49

Flue block sensor faulty

Service call

 

 

 

53

Spark sensor faulty

Service call

 

 

 

61

Fan motor faulty

Service call

 

 

 

71

Solenoids faulty

Service call

 

 

 

72

Flame detection circuit fault

Service call

 

 

 

73

Communication fault

Service call

 

 

 

99

Flue block

Check around flue terminal for obstructions to air flow

 

 

 

Replacement of Thermal Fuse

The cause of the overheat condition needs to be

Thermal Fuse

 

determined and remedied before replacing the

 

thermal fuse.

 

A qualified service technician needs to:

1. Disconnect the appliance from the power supply.

2. Remove the right hand side panel to allow access to the gas control and main PCB.

3. Unplug the thermal fuse harness (including the control plug for the POV on the gas control) and unscrew thermal fuse.

4. Re-assemble with replacement thermal fuse.

PCB

POV

14